Utilize este identificador para referenciar este registo:
http://hdl.handle.net/10400.5/96650
Registo completo
Campo DC | Valor | Idioma |
---|---|---|
degois.publication.firstPage | 1 | pt_PT |
degois.publication.lastPage | 4 | pt_PT |
degois.publication.location | Madrid, Espanha | pt_PT |
dc.contributor.author | Pelicano, Ana Catarina | - |
dc.contributor.author | Araujo, Nuno A. M. | - |
dc.contributor.author | Conceicao, Raquel C. | - |
dc.date.accessioned | 2024-12-20T18:34:05Z | - |
dc.date.available | 2024-12-20T18:34:05Z | - |
dc.date.issued | 2022 | - |
dc.identifier.uri | http://hdl.handle.net/10400.5/96650 | - |
dc.description.abstract | In this work, we present a preliminary study of three classifiers – Linear Discriminant Analysis (LDA), Support Vector Machines (SVMs) and k-Nearest Neighbors (kNN) – to differentiate between malignant and benign tumors extracted from Magnetic Resonance (MR) images, based on their morphological features. The dataset in this study comprises 24 tumors: 12 malignant and 12 benign. Twelve morphological features were initially considered for tumor classification. The Mann-Whitney test was employed for feature selection, and the performance of the classifiers was evaluated with accuracy, sensitivity, specificity, F1-score and Matthew’s Correlation Coefficient (MCC) metrics. kNN (with k=6 and Chebyshev distance) outperformed the other classifiers with an accuracy, sensitivity, and specificity of 87.5%, 83.3% and 91.7%, respectively. | pt_PT |
dc.language.iso | eng | pt_PT |
dc.relation | Fundação para a Ciência e Tecnologia (FCT): UI/BD/150762/2020 | pt_PT |
dc.relation | Fundação para a Ciência e Tecnologia (FCT): UIDB/00645/2020 | pt_PT |
dc.relation | Fundação para a Ciência e Tecnologia (FCT): PTDC/FISMAC/28146/2017 (LISBOA-01-0145-FEDER-028146) | pt_PT |
dc.relation | Fundação para a Ciência e Tecnologia: UIDB/00618/2020 | pt_PT |
dc.relation | Fundação para a Ciência e Tecnologia: UIDP/00618/2020 | pt_PT |
dc.rights | openAccess | pt_PT |
dc.subject | breast cancer | pt_PT |
dc.subject | tumor classification | pt_PT |
dc.subject | morphological features | pt_PT |
dc.title | Preliminary development of anatomically realistic breast tumor models for microwave imaging | pt_PT |
dc.type | article | pt_PT |
dc.description.version | info:eu-repo/semantics/publishedVersion | pt_PT |
dc.peerreviewed | yes | pt_PT |
dc.identifier.doi | 10.23919/EuCAP53622.2022.9769591 | pt_PT |
Aparece nas colecções: | IBEB - Artigos em Conferências |
Ficheiros deste registo:
Ficheiro | Descrição | Tamanho | Formato | |
---|---|---|---|---|
Preliminary development of anatomically realistic breast tumor models for microwave imaging.pdf | 268,69 kB | Adobe PDF | Ver/Abrir |
Todos os registos no repositório estão protegidos por leis de copyright, com todos os direitos reservados.