Repository logo
 
Publication

Aortic dissection repair using the STABILISE technique associated with arch procedures : report of two cases

dc.contributor.authorLopes, Alice
dc.contributor.authorMelo, Ryan
dc.contributor.authorGomes, Miguel L.
dc.contributor.authorGarrido, Pedro
dc.contributor.authorJunqueira, Nádia
dc.contributor.authorSobrinho, Gonçalo
dc.contributor.authorFernandes E Fernandes, Ruy
dc.contributor.authorLeitão, João
dc.contributor.authorNobre, Ângelo
dc.contributor.authorPedro, Luís M
dc.date.accessioned2020-11-11T12:37:26Z
dc.date.available2020-11-11T12:37:26Z
dc.date.issued2019
dc.description© 2019 The Authors. Published by Elsevier Ltd on behalf of European Society for Vascular Surgery. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).pt_PT
dc.description.abstractIntroduction: The stent assisted balloon induced intimal disruption and relamination in aortic dissection repair (STABILISE) technique is being increasingly used for the treatment of complicated aortic dissections. However, as it is a fairly recent technique, the scientific information is limited. Report: In this paper we report two cases of the STABILISE technique associated with procedures in the ascending aorta and supra-aortic trunks, consisting of a “frozen elephant trunk” procedure in one case and in the other, a carotid endarterectomy associated with reimplantation of the vertebral artery and partial arch debranching. Discussion: In conclusion, while acknowledging the need for longer follow up and greater experience to support the safety and efficacy of this procedure, the two cases reported confirm that the STABILISE technique is a valid endovascular alternative in the treatment of complicated aortic dissections.pt_PT
dc.description.versioninfo:eu-repo/semantics/publishedVersionpt_PT
dc.identifier.citationEJVES Short Rep. 2019 Feb 13;42:26-30pt_PT
dc.identifier.doi10.1016/j.ejvssr.2019.01.003pt_PT
dc.identifier.issn2405-6553
dc.identifier.urihttp://hdl.handle.net/10451/44833
dc.language.isoengpt_PT
dc.peerreviewedyespt_PT
dc.publisherElsevierpt_PT
dc.relation.publisherversionhttps://www.ejvesreports.com/pt_PT
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/pt_PT
dc.subjectAortic dissectionpt_PT
dc.subjectSTABILISEpt_PT
dc.subjectBare stentpt_PT
dc.subjectStent graftpt_PT
dc.subjectEndovascularpt_PT
dc.titleAortic dissection repair using the STABILISE technique associated with arch procedures : report of two casespt_PT
dc.typejournal article
dspace.entity.typePublication
oaire.citation.endPage30pt_PT
oaire.citation.startPage26pt_PT
oaire.citation.titleEJVES Short Reportspt_PT
oaire.citation.volume42pt_PT
person.familyNameGouveia e Melo
person.familyNameSobrinho
person.familyNameFernandes e Fernandes
person.familyNamePedro
person.givenNameRyan
person.givenNameGonçalo
person.givenNameRuy
person.givenNameLuís
person.identifier.ciencia-id211B-B548-CE4E
person.identifier.ciencia-id3514-2431-1C78
person.identifier.ciencia-idB710-641D-77AD
person.identifier.ciencia-id0B14-1812-24DC
person.identifier.orcid0000-0001-8327-6384
person.identifier.orcid0000-0003-1050-4715
person.identifier.orcid0000-0003-1619-8851
person.identifier.orcid0000-0003-4310-9324
person.identifier.scopus-author-id8256157300
person.identifier.scopus-author-id39761284300
person.identifier.scopus-author-id7004454630
rcaap.rightsopenAccesspt_PT
rcaap.typearticlept_PT
relation.isAuthorOfPublication5b231766-381e-40e7-ad60-f2e414c2eb38
relation.isAuthorOfPublication59690318-8ed6-455f-a593-dab81a172444
relation.isAuthorOfPublication8b4cff45-1799-4e5c-9d7b-61405e351329
relation.isAuthorOfPublicationff4d548a-318e-4368-b735-e8b82e060dd3
relation.isAuthorOfPublication.latestForDiscoveryff4d548a-318e-4368-b735-e8b82e060dd3

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
STABILISE.pdf
Size:
1.04 MB
Format:
Adobe Portable Document Format