Logo do repositório
 
Publicação

MitraClip in tricuspid regurgitation : current evidence

datacite.subject.fosCiências Médicaspt_PT
dc.contributor.advisorCaldeira, Daniel
dc.contributor.advisorGuerra, Nuno Miguel Nobre Carvalho
dc.contributor.authorCarmali, Diogo Karim Hassam
dc.date.accessioned2023-03-23T14:28:09Z
dc.date.available2024-05-30T00:30:40Z
dc.date.issued2022-07
dc.descriptionTrabalho Final do Curso de Mestrado Integrado em Medicina, Faculdade de Medicina, Universidade de Lisboa, 2022pt_PT
dc.description.abstractA Regurgitação Tricúspide afeta 65-85% da população e estÔ associada a um risco de mortalidade consideravelmente elevado. As opções terapêuticas disponíveis para doentes de alto risco cirúrgico são limitadas. O MitraClip, previamente aprovado para a regurgitação mitral, é um dispositivo percutâneo promissor em investigação para o tratamento desta patologia. A presente dissertação pretende elucidar sobre os desenvolvimentos no uso do MitraClip na Regurgitação Tricúspide, desde estudos em modelo ex-vivo até estudos de imagem e ensaios clínicos. Mais ainda, descreve também a técnica de colocação do MitraClip e aborda os estudos mais recentes com enfoque neste dispositivo. Os estudos descritos no presente trabalho sugerem que a implementação do MitraClip é viÔvel, segura e duradoura até pelo menos 1 ano em doentes de alto risco cirúrgico, demonstrando benefícios clínicos persistentes no tempo, nomeadamente, a redução do grau de regurgitação tricúspide, redução na Classificação Funcional da New York Heart Association e melhoria no teste de marcha de 6 minutos. A sua implementação em doentes de alto risco cirúrgico, para além de motivar um remodelling cardíaco reverso positivo e de ser mais vantajosa que a terapêutica médica isolada, não estÔ associada a efeitos adversos cardíacos major. Não foram encontradas diferenças significativas no uso do MitraClip em abordagens isoladas à vÔlvula tricúspide e em abordagens combinadas com correção de patologia mitral. Menores coaptation gaps e localização não central/antero-septal do jato de regurgitação foram identificados como preditores de sucesso do procedimento. Valores elevados de tenting area e de EROA foram definidos como preditores ecocardiogrÔficos de insucesso. Indivíduos com o diagnóstico de Hipertensão Pulmonar confirmado invasivamente e por ecocardiografia apresentam valores de event-free survival time sobreponíveis aos de indivíduos sem Hipertensão Pulmonar sugerindo o possível potencial terapêutico das intervenções percutâneas nestas populações e a necessidade de redefinição de critérios de exclusão em estudos futuros.pt_PT
dc.description.abstractTricuspid Regurgitation is a condition affecting 65-85% of the population that carries reasonable high mortality risk. Current treatment options are limited and far from ideal, particularly in high surgical risk patients. The development of new transcatheter devices may offer some therapeutic answers to some of these high risk patients. The MitraClip, previously approved for patients with mitral regurgitation, is a promising percutaneous device currently being tested for right heart disease. The present dissertation aims to shed light on how far we have come on the use of the MitraClip in Tricuspid Regurgitation, from ex-vivo studies to imaging studies and clinical trials. Moreover, it also describes the device’s procedural technique and outlines recent data on the studies using this transcatheter edge-to-edge device. The studies described suggest that MitraClip implementation is feasible, safe and durable over 1 year in patients at high prohibitive surgical risk with persistent clinical results over time, namely reduction in tricuspid regurgitation grade of severity and functional parameters such as NYHA Functional Class and 6-min walking test. Its use is associated with positive reverse cardiac remodeling but not with increased major adverse cardiac or cerebrovascular effects, comparing favorably to alone medical therapy. There are no significant differences on the use of the MitraClip in isolated tricuspid or combined mitral valve approaches. Small coaptation gaps as well as non-central/anteroseptal location of regurgitant jet are identified as predictors of procedural success, while greater tricuspid Tenting Area and larger EROA are defined as echocardiographic predictors of procedural failure. Patients with Pulmonary Hypertension confirmed invasively and echocardiographically had similar event-free survival time after MitraClip implantation in comparison to patients without Pulmonary Hypertension suggesting a need for redefinition of inclusion criteria in future studies and highlighting the potential role of transcatheter valve therapies in these patients.pt_PT
dc.identifier.tid203139925pt_PT
dc.identifier.urihttp://hdl.handle.net/10451/56784
dc.language.isoengpt_PT
dc.subjectMitraClippt_PT
dc.subjectRegurgitação tricúspidept_PT
dc.subjectReparação percutânea da vÔlvula tricúspidept_PT
dc.subjectCardiologiapt_PT
dc.titleMitraClip in tricuspid regurgitation : current evidencept_PT
dc.typemaster thesis
dspace.entity.typePublication
rcaap.rightsopenAccesspt_PT
rcaap.typemasterThesispt_PT
thesis.degree.nameMestrado Integrado em Medicinapt_PT

Ficheiros

Principais
A mostrar 1 - 1 de 1
A carregar...
Miniatura
Nome:
DiogoKCarmali.pdf
Tamanho:
1010.18 KB
Formato:
Adobe Portable Document Format
LicenƧa
A mostrar 1 - 1 de 1
Miniatura indisponĆ­vel
Nome:
license.txt
Tamanho:
1.2 KB
Formato:
Item-specific license agreed upon to submission
Descrição: