Logo do repositório
 
Publicação

Teste de microtração em esmalte de um sistema adesivo universal pela técnica etch-and-rinse e etch-and-dry

datacite.subject.fosCiências Médicas::Medicina Clínicapt_PT
dc.contributor.advisorSousa, Bernardo Romão de
dc.contributor.advisorPequeno, Ana
dc.contributor.authorPeneque, Carolina Martins Santos
dc.date.accessioned2016-12-27T16:12:27Z
dc.date.available2016-12-27T16:12:27Z
dc.date.issued2014
dc.date.submitted2014
dc.descriptionTese de mestrado, Medicina dentária, Universidade de Lisboa, Faculdade de Medicina Dentária, 2014pt_PT
dc.description.abstractObjetivo: Recorrendo ao teste de microtração, avaliar e comparar as forças adesivas em esmalte cortado de um sistema adesivo universal (Scotchbond Universal Adhesive, 3M ESPE, St. Paul, MN, USA) usado segundo as instruções do fabricante, nos modos etch-and-rinse e etch-and-dry. A hipótese nula testada é a de que não existem diferenças estatisticamente significativas nas forças de adesão ao esmalte cortado entre as duas estratégias de adesão propostas pelo fabricante para o mesmo adesivo universal. Materiais e Métodos: Foi usada uma amostra de oito terceiros molares humanos. Cortaram-se as superfícies coronárias no sentido mesio-distal, de forma a obter dois segmentos de coroa por dente. Os dentes foram aleatoriamente distribuídos por um dos grupos de teste, de acordo com a estratégia de adesão: SBU aplicado como self-etch de um passo (SBU SE); SBU aplicado como etch-and-rinse de dois passos (SBU TE). Nos segmentos de coroa do grupo SBU TE foi realizado condicionamento com ácido ortofosfórico a 32% (Scotchbond Universal Etchant, 3M ESPE, St Paul, MN), durante 15 segundos. Foram aplicados incrementos de compósito sobre as superfícies dentárias preparadas, até perfazer uma altura de aproximadamente 6 mm. Após 24h numa estufa de incubação a 37º, os dentes foram seccionados de forma a obter palitos com uma área de aproximadamente 1 mm2. Os palitos foram submetidos a uma força de tração, a uma velocidade de 1 mm/minuto. A análise estatística foi realizada com o teste t para amostras independentes. Resultados: As forças médias de resistência à microtração (em MPa) e desvios padrão em cada grupo foram: SBU TE = 22,8 (12,3); SBU SE = 14,3 (6,7). Verificaram-se diferenças estatisticamente significativas entre os grupos (p = 0,000). Conclusões: A hipótese nula foi rejeitada. O condicionamento ácido da superfície do esmalte cortado aumentou significativamente as forças de adesão produzidas pelo sistema adesivo Scotchbond Universal Adhesive.pt_PT
dc.description.abstractObjective: To evaluate microtensile bond strength (μTBS) to bur cut enamel of a new universal adhesive (SBU Scotchbond Universal Adhesive, 3M ESPE, St Paul, MN) used according to the manufacturers’ instructions, in the etch-and-rinse and etch-and-dry modes. The null hypothesis tested was that there were no differences in enamel microtensile bond strengths (μTBS) among these two different adhesion strategies. Materials and Methods: Eight human third molars were sectioned to obtain two enamel fragments. The enamel surfaces were roughened with a diamond bur in a standardized procedure. Teeth were randomly assigned to two groups, according to the adhesive strategy: SBU applied as one-step self-etch adhesive (SBU SE); SBU applied as two-step etch-and-rinse adhesive (SBU TE). The etched specimens were previously conditioned with 32% phosphoric acid (Scotchbond Universal Etchant, 3M ESPE, St Paul, MN), for 15 seconds. Composite resin blocks (ENAMEL plus HRi, Micerium S.p.A. Avegno GE Italy) of approximately 6 mm were then incrementally built up over the prepared tooth substrate. After 24h of water storage (37º), the bonded specimens were sectioned into beams with a cross sectional area of 1 mm2 and tested under tension (1 mm/min). The data were analyzed with an independent-sample t test, when the assumption of normality was valid. Results: The μTBS (MPa) and standard deviations were: SBU TE = 22,8 (12,3); SBU SE = 14,3 (6,7). These values were statistically significantly different. Conclusions: The null hypothesis was rejected. Preliminary etching of enamel significantly increased bond strength for the universal adhesive Scotchbond Universal Adhesivept_PT
dc.identifier.tid201267853pt_PT
dc.identifier.urihttp://hdl.handle.net/10451/25416
dc.language.isoporpt_PT
dc.subjectMateriais dentários - esmalte - adesivospt_PT
dc.subjectTeses de mestrado - 2014pt_PT
dc.titleTeste de microtração em esmalte de um sistema adesivo universal pela técnica etch-and-rinse e etch-and-drypt_PT
dc.typemaster thesis
dspace.entity.typePublication
rcaap.rightsopenAccesspt_PT
rcaap.typemasterThesispt_PT
thesis.degree.nameMestrado Integrado em Medicina Dentáriapt_PT

Ficheiros

Principais
A mostrar 1 - 1 de 1
A carregar...
Miniatura
Nome:
ulfmd02999_tm_Carolina_Peneque.pdf
Tamanho:
1.36 MB
Formato:
Adobe Portable Document Format
Licença
A mostrar 1 - 1 de 1
Miniatura indisponível
Nome:
license.txt
Tamanho:
1.2 KB
Formato:
Item-specific license agreed upon to submission
Descrição: