Reparação de compósitos: influência do tratamento de superfície e do envelhecimento em elixires na força da adesão

datacite.subject.fosCiências Médicas::Medicina Clínicapt_PT
dc.contributor.advisorPortugal, Jaime, 1969-
dc.contributor.authorPinheiro, Inês Sofia Antunes Pinto
dc.date.accessioned2017-02-22T13:08:24Z
dc.date.available2017-02-22T13:08:24Z
dc.date.issued2012
dc.date.submitted2012
dc.descriptionTese de mestrado, Medicina Dentária, Universidade de Lisboa, Faculdade de Medicina Dentária, 2012pt_PT
dc.description.abstractObjetivos: 1) avaliar a influência do envelhecimento artificial em elixires orais e de diferentes tratamentos mecânicos de superfície na resistência adesiva da reparação de resinas compostas; e 2) determinar a influência dos meios de envelhecimento artificial na microdureza do compósito envelhecido. Materiais e Métodos: Foram preparados 120 discos de compósito nanohíbrido (GrandioSO, VOCO) com forma e dimensão padronizados e divididos aleatoriamente em 4 grupos (n=30), de acordo com o meio de envelhecimento utilizado (Listerine, Eludril Perio, Lacer Ouros e Água destilada). Após um período de 5 dias em estufa (37ºC, 100% de humidade relativa), durante os quais os espécimes foram submetidos a 12 ciclos de imersão de 2 horas nos respetivos meios de envelhecimento, foi determinada a microdureza Knoop. Seguidamente, cada grupo foi dividido em 3 subgrupos de acordo com o tratamento mecânico de superfície (jacteamento com partículas de óxido de alumínio de 50 μm, tratamento abrasivo com broca diamantada e nenhum tratamento) realizado. Foram constituídos 12 grupos experimentais (n=10). 24 Horas após a reparação do compósito, com um sistema adesivo (Solobond M, VOCO) e compósito (GrandioSO, VOCO), realizaram-se ensaios de resistência à fratura sob tensões de corte, seguindo-se a análise da falha produzida. Resultados: Os valores médios de microdureza variaram entre 469,43HK e 530,31HK. O grupo experimental da água destilada apresentou valores de microdureza estatisticamente (p<0,05) mais elevados. Não se verificaram diferenças significativas (p≥0,05) entre os elixires. Os valores médios de resistência adesiva variaram entre 36,21MPa e 50,41MPa mas não foram influenciados de forma estatisticamente significativa nem pelo tratamento de superfície (p=0,165), nem pelo método de envelhecimento (p=0,214). Para o tipo de falha produzida, também não se observaram diferenças estatisticamente significativas (p≥0,05) entre grupos. Conclusões: Apesar da microdureza do compósito ser influenciada negativamente pelo contacto com os elixires orais estudados, a resistência adesiva do compósito reparado não é afetada.pt_PT
dc.description.abstractObjectives: 1) to assess the influence of mechanical surface treatments and artificial aging in mouthwashes, on the shear bond strength of repaired composite resin; and 2) to evaluate the effect of the mouthwashes on the composite Knoop microhardness. Materials and Methods: 120 composite resin (GrandioSO, VOCO) specimens with standardized shape and size were prepared, and randomly divided into 4 groups (n=30), according the used aging media. After a period of 5 days in an oven (37ºC with a relative humidity of 100%), during which were submitted to 12 cycles of 2 hours of immersion in the respective aging media, the Knoop microhardness was determined. Then, each group was divided into 3 groups based on the mechanical surface treatment performed (sandblastlasting with aluminum oxide particles, abrasion using a diamond bur and no treatment). Thus, 12 experimental groups were created (n=10). 24 hours after the repair of the composite, which was performed using an adhesive system (Solobond M VOCO) and composite (Grand VOCO), the specimens were loaded to failure in shear mode, followed by the analysis of the produced failure. Results: The mean microhardness values ranged from 469,43HK to 530,31HK. The group of specimens aged in distilled water presented significantly harder surface then the other experimental groups (p<0,05). No statistically significant differences were found (p≥0,05) between other groups. The mean bond strength ranged between 36,21MPa and 50,41MPa, but none the immersion media (p=0,214) nor the mechanical surface treatments (p=0,165) had significant effect on the bond strength. Regarding the failure type, there was no statistically significant differences (p≥0,05) between groups. Conclusions: In spite of the fact that hardness of the composite is negatively affected by contact with the mouthwashes used in this study, the bond strength of composite repair is not affected.pt_PT
dc.identifier.tid201607565pt_PT
dc.identifier.urihttp://hdl.handle.net/10451/26625
dc.language.isoporpt_PT
dc.subjectMateriais dentáriospt_PT
dc.subjectTeses de mestrado - 2012pt_PT
dc.titleReparação de compósitos: influência do tratamento de superfície e do envelhecimento em elixires na força da adesãopt_PT
dc.typemaster thesis
dspace.entity.typePublication
rcaap.rightsopenAccesspt_PT
rcaap.typemasterThesispt_PT
thesis.degree.nameMestrado Integrado em Medicina Dentáriapt_PT

Ficheiros

Principais
A mostrar 1 - 1 de 1
A carregar...
Miniatura
Nome:
ulfmd07007_tm_Ines_Pinheiro.pdf
Tamanho:
1.43 MB
Formato:
Adobe Portable Document Format
Licença
A mostrar 1 - 1 de 1
Miniatura indisponível
Nome:
license.txt
Tamanho:
1.2 KB
Formato:
Item-specific license agreed upon to submission
Descrição: