Repository logo
 
Publication

Effect of Varying Prior Information in Axillary 2D Microwave Tomography

dc.contributor.authorSavazzi, Matteo
dc.contributor.authorKaradima, Olympia
dc.contributor.authorFelicio, Joao M.
dc.contributor.authorFernandes, Carlos A.
dc.contributor.authorKosmas, Panagiotis
dc.contributor.authorConceicao, Raquel C.
dc.date.accessioned2022-06-10T15:45:50Z
dc.date.available2022-06-10T15:45:50Z
dc.date.issued2022
dc.description.abstractWe numerically assess the potential of microwave tomography (MWT) for the detection and dielectric properties estimation of axillary lymph nodes (ALNs), and we study the robustness of our system using prior information with varying levels of accuracy. We adopt a 2-dimensional MWT system with 8 antennas (0.5-2.5 GHz) placed around the axillary region. The reconstruction algorithm implements the distorted Born iterative method. We show that: (i) when accurate prior knowledge of the axillary tissues (fat and muscle) is available, our system successfully detects an ALN; (ii) ±30% error in the prior estimation of fat and muscle dielectric properties does not affect image quality; (iii) ±7mm error in muscle position causes slight artifacts, while ± 14mm error in muscle position affects ALN detection. To the best of our knowledge, this is the first paper in the literature to study the impact of prior information accuracy on detecting an ALN using MWT.pt_PT
dc.description.versioninfo:eu-repo/semantics/publishedVersionpt_PT
dc.identifier.doi10.23919/EuCAP53622.2022.9769372pt_PT
dc.identifier.isbn978-88-31299-04-6
dc.identifier.urihttp://hdl.handle.net/10451/53367
dc.language.isoengpt_PT
dc.peerreviewedyespt_PT
dc.relationH2020 MSCA-ITN EMERALD GA number 764479pt_PT
dc.relationFundação para a Ciência e a Tecnologia-FCT, FCT/MEC (PIDDAC) under the Strategic Programme UIDB/00645/2020pt_PT
dc.relationFundação para a Ciência e a Tecnologia-FCT, UIDB/EEA/50008/2020pt_PT
dc.subjectaxillary lymph node imagingpt_PT
dc.subjectbreast cancerpt_PT
dc.subjectdistorted Born iterative method (DBIM)pt_PT
dc.subjectmicrowave tomographypt_PT
dc.subjectprior informationpt_PT
dc.titleEffect of Varying Prior Information in Axillary 2D Microwave Tomographypt_PT
dc.typejournal article
dspace.entity.typePublication
oaire.citation.conferencePlaceMadrid, Spainpt_PT
oaire.citation.endPage5pt_PT
oaire.citation.startPage1pt_PT
oaire.citation.title16th European Conference on Antennas and Propagation (EuCAP)pt_PT
rcaap.rightsopenAccesspt_PT
rcaap.typearticlept_PT

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
1570770752 final.pdf
Size:
2.56 MB
Format:
Adobe Portable Document Format