Machine learning for the real-time assessment of left ventricular ejection fraction in critically ill patients: a bedside evaluation by novices and experts in echocardiography

Use this identifier to reference this record.
Name:Description:Size:Format: 
Machine_learning.pdf919.34 KBAdobe PDF Download

Advisor(s)

Abstract(s)

Background: Machine learning algorithms have recently been developed to enable the automatic and real-time echocardiographic assessment of left ventricular ejection fraction (LVEF) and have not been evaluated in critically ill patients. Methods: Real-time LVEF was prospectively measured in 95 ICU patients with a machine learning algorithm installed on a cart-based ultrasound system. Real-time measurements taken by novices (LVEFNov) and by experts (LVEFExp) were compared with LVEF reference measurements (LVEFRef) taken manually by echo experts. Results: LVEFRef ranged from 26 to 80% (mean 54 ± 12%), and the reproducibility of measurements was 9 ± 6%. Thirty patients (32%) had a LVEFRef < 50% (left ventricular systolic dysfunction). Real-time LVEFExp and LVEFNov measurements ranged from 31 to 68% (mean 54 ± 10%) and from 28 to 70% (mean 54 ± 9%), respectively. The reproducibility of measurements was comparable for LVEFExp (5 ± 4%) and for LVEFNov (6 ± 5%) and significantly better than for reference measurements (p < 0.001). We observed a strong relationship between LVEFRef and both real-time LVEFExp (r = 0.86, p < 0.001) and LVEFNov (r = 0.81, p < 0.001). The average difference (bias) between real time and reference measurements was 0 ± 6% for LVEFExp and 0 ± 7% for LVEFNov. The sensitivity to detect systolic dysfunction was 70% for real-time LVEFExp and 73% for LVEFNov. The specificity to detect systolic dysfunction was 98% both for LVEFExp and LVEFNov. Conclusion: Machine learning-enabled real-time measurements of LVEF were strongly correlated with manual measurements obtained by experts. The accuracy of real-time LVEF measurements was excellent, and the precision was fair. The reproducibility of LVEF measurements was better with the machine learning system. The specificity to detect left ventricular dysfunction was excellent both for experts and for novices, whereas the sensitivity could be improved.

Description

© The Author(s) 2022. Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Keywords

Artificial intelligence Echocardiography Left ventricular ejection fraction Machine learning Novice Point of care ultrasound

Pedagogical Context

Citation

Crit Care. 2022 Dec 14;26(1):386