Utilize este identificador para referenciar este registo: http://hdl.handle.net/10451/62522
Registo completo
Campo DCValorIdioma
degois.publication.firstPagee078425pt_PT
degois.publication.issue2pt_PT
degois.publication.titleBMJ Openpt_PT
dc.relation.publisherversionhttps://bmjopen.bmj.com/pt_PT
dc.contributor.authorGonçalves, Tânia-
dc.contributor.authorCarlos Winck, João-
dc.contributor.authorSilva, Fátima-
dc.contributor.authorCaneiras, Catia-
dc.contributor.authorMontes, António Mesquita-
dc.contributor.authorVilarinho, Rui-
dc.date.accessioned2024-02-08T14:45:30Z-
dc.date.available2024-02-08T14:45:30Z-
dc.date.issued2024-
dc.identifier.citationBMJ Open. 2024 Feb 7;14(2):e078425pt_PT
dc.identifier.urihttp://hdl.handle.net/10451/62522-
dc.description© Author(s) (or their employer(s)) 2024. Re-use permitted under CC BY-NC. No commercial re-use. See rights and permissions. Published by BMJ. This is an open access article distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited, appropriate credit is given, any changes made indicated, and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/.pt_PT
dc.description.abstractObjectives: The new incremental step test (IST) is a field test that was developed for people with chronic obstructive pulmonary disease (COPD), based on the characteristics of the incremental shuttle walk test (ISWT); however, its measurement properties still need to be determined. We aimed, first, to assess the construct validity (through the comparison with the ISWT), within-day reliability and measurement error of the IST in people with COPD; and, second, to identify whether the participants have a learning effect in the IST. Design: Cross-sectional study, conducted according to COnsensus-based Standards for the selection of health status Measurement INstruments guidelines. Setting: A family health unit in Portugal, April 2022 to June 2023. Participants and analysis: 63 participants (67.5±10.5 years) attended two sessions to perform two IST and two ISWT, separately. Spearman's correlations were used to compare the best performances between the IST and the ISWT. Intraclass correlation coefficient (ICC2,1) was used for reliability, and the SE of measurement (SEM), minimal detectable change at 95% CI (MDC95) and Bland and Altman 95% limits of agreement (LoA) were used for measurement error. The learning effect was explored with the Wilcoxon signed-rank test. Results: The IST was significant and strongly correlated with the ISWT (0.72<ρ<0.74, p<0.001), presented an ICC2,1 of 0.95 (95% CI 0.92 to 0.97), SEM=11.7 (18.9%), MDC95=32.4 (52.2%) and the LoA were -33.61 to 31.48 for the number of steps. No difference was observed between the number of steps of the two attempts of the IST (p>0.05). Conclusions: The IST can be suggested as a valid and reliable test to assess exercise capacity in people with COPD, with no learning effect when two IST are performed on the same day. The measurement error of the IST is considered indeterminate. Trial registration number: NCT04715659.pt_PT
dc.language.isoengpt_PT
dc.publisherBMJ Publishing Grouppt_PT
dc.rightsopenAccesspt_PT
dc.rights.urihttp://creativecommons.org/licenses/by-nc/4.0/pt_PT
dc.subjectChronic airways diseasept_PT
dc.subjectGeriatric medicinapt_PT
dc.subjectRehabilitation medicinept_PT
dc.titleMeasurement properties of the incremental step test for people with chronic obstructive pulmonary disease: a cross-sectional studypt_PT
dc.typearticlept_PT
dc.description.versioninfo:eu-repo/semantics/publishedVersionpt_PT
dc.peerreviewedyespt_PT
degois.publication.volume14pt_PT
dc.identifier.doi10.1136/bmjopen-2023-078425pt_PT
dc.identifier.eissn2044-6055-
Aparece nas colecções:FM-ISAMB-Artigos em Revistas Internacionais
FM-IMPSP-Artigos em Revistas Internacionais

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
Measurement_properties.pdf748 kBAdobe PDFVer/Abrir


FacebookTwitterDeliciousLinkedInDiggGoogle BookmarksMySpace
Formato BibTex MendeleyEndnote 

Todos os registos no repositório estão protegidos por leis de copyright, com todos os direitos reservados.