Utilize este identificador para referenciar este registo: http://hdl.handle.net/10451/56369
Título: Validity and reliability of a new incremental step test for people with chronic obstructive pulmonary disease
Autor: Vilarinho, Rui
Serra, Lúcia
Águas, Ana
Alves, Carlos
Silva, Pedro Matos
Caneiras, Catia
Montes, António Mesquita
Palavras-chave: Exercise
Pulmonary rehabilitation
Respiratory measurement
Data: 2022
Editora: BMJ Publishing Group
Citação: BMJ Open Respir Res. 2022 Apr;9(1):e001158
Resumo: Background: Incremental step tests (IST) can be used to assess exercise capacity in people with chronic obstructive pulmonary disease (COPD). The development of a new step test based on the characteristics of the incremental shuttle walk test (ISWT) is an important study to explore. We aimed to develop a new IST based on the ISWT in people with COPD, and assess its validity (construct validity) and reliability, according to Consensus-based Standards for the selection of health status Measurement Instruments (COSMIN) recommendations. Methods: A cross-sectional study was conducted in participants recruited from hospitals/clinics. During the recruitment, the participants who presented a 6-minute walk test (6MWT) report in the previous month were also identified and the respective data was collected. Subsequently, participants attended two sessions at their homes. IST was conducted on the first visit, along with the 1 min sit-to-stand (1MSTS) test. IST was repeated on a second visit, performed 5-7 days after the first one. Spearman's correlations were used for construct validity, by comparing the IST with the 6MWT and the 1MSTS. Intraclass correlation coefficient (ICC2,1), SE of measurement (SEM) and minimal detectable change at 95% CI (MDC95) were used for reliability. The learning effect was explored with the Wilcoxon signed-rank test. Results: 50 participants (70.8±7.5 years) were enrolled. IST was significant and moderate correlated with the 6MWT (ρ=0.50, p=0.020), and with the 1MSTS (ρ=0.46, p=0.001). IST presented an ICC2,1=0.96, SEM=10.1 (16.6%) and MDC95=27.9 (45.8%) for the number of steps. There was a statistically significant difference between the two attempts of the IST (p=0.030). Conclusion: Despite the significant and moderate correlations with the 6MWT and 1MSTS, the inability to full compliance with the COSMIN recommendations does not yet allow the IST to be considered valid in people with COPD. On the other hand, the IST is a reliable test based on its high ICC, but a learning effect and an 'indeterminate' measurement error were shown.
Descrição: © Author(s) (or their employer(s)) 2022. Re-use permitted under CC BY-NC. No commercial re-use. See rights and permissions. Published by BMJ. http://creativecommons.org/licenses/by-nc/4.0/This is an open access article distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited, appropriate credit is given, any changes made indicated, and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/.
Peer review: yes
URI: http://hdl.handle.net/10451/56369
DOI: 10.1136/bmjresp-2021-001158
Versão do Editor: https://bmjopenrespres.bmj.com/
Aparece nas colecções:FM-IMPSP-Artigos em Revistas Internacionais
FM-ISAMB-Artigos em Revistas Internacionais

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
Validity_reliability.pdf628,52 kBAdobe PDFVer/Abrir


FacebookTwitterDeliciousLinkedInDiggGoogle BookmarksMySpace
Formato BibTex MendeleyEndnote 

Todos os registos no repositório estão protegidos por leis de copyright, com todos os direitos reservados.