Utilize este identificador para referenciar este registo: http://hdl.handle.net/10451/53513
Registo completo
Campo DCValorIdioma
degois.publication.firstPage1pt_PT
degois.publication.lastPage5pt_PT
degois.publication.locationDusseldorf, Germanypt_PT
dc.contributor.authorGodinho, Daniela M.-
dc.contributor.authorFelicio, Joao M.-
dc.contributor.authorFernandes, Carlos A.-
dc.contributor.authorConceicao, Raquel C.-
dc.date.accessioned2022-06-27T22:23:43Z-
dc.date.available2022-06-27T22:23:43Z-
dc.date.issued2021-
dc.identifier.urihttp://hdl.handle.net/10451/53513-
dc.description.abstractMicrowave Imaging (MWI) has the potential to aid breast cancer staging through the detection of Axillary Lymph Nodes (ALNs). This type of system can present some challenges, mainly due to the irregular axillary surface. The optimisation of the artefact removal algorithm to successfully remove the surface reflections is of great importance. In this paper, we propose using Singular Value Decomposition (SVD) as an artefact removal algorithm and study the effect of choosing different subsets of antenna positions for artefact removal on imaging results using experimental signals. We show that different subsets of antenna positions affect the results and in some cases prevent the targets detection. Our analysis allowed us to find an optimal combination of parameters which results in Signal-to-Clutter Ratio higher than 2.77 dB and Location Error lower than 14.9 mm for three different experimental tests. These results are relevant for the development of dedicated algorithms for ALN-MWI application.pt_PT
dc.language.isoengpt_PT
dc.relationFundação para a Ciência e a Tecnologia-FCT under the fellowship SFRH/BD/129230/2017pt_PT
dc.relationFundação para a Ciência e a Tecnologia-FCT/MEC (PIDDAC) under the Strategic Programme UIDB/00645/2020pt_PT
dc.relationFundação para a Ciência e a Tecnologia-FEDER-PT2020 Partnership Agreement under Grant UIDB/EEA/50008/2020pt_PT
dc.relationCOST Action CA17115 – MyWAVEpt_PT
dc.rightsopenAccesspt_PT
dc.subjectartefact removal algorithmpt_PT
dc.subjectaxillary lymph nodespt_PT
dc.subjectbreast cancerpt_PT
dc.subjectmicrowave imagingpt_PT
dc.titleOptimisation of Artefact Removal Algorithm for Microwave Imaging of the Axillary Region Using Experimental Prototype Signalspt_PT
dc.typearticlept_PT
dc.description.versioninfo:eu-repo/semantics/publishedVersionpt_PT
dc.peerreviewedyespt_PT
dc.identifier.doi10.23919/EuCAP51087.2021.9411134pt_PT
Aparece nas colecções:IBEB - Artigos em Conferências

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
__2021EuCAP.pdf5,11 MBAdobe PDFVer/Abrir


FacebookTwitterDeliciousLinkedInDiggGoogle BookmarksMySpace
Formato BibTex MendeleyEndnote 

Todos os registos no repositório estão protegidos por leis de copyright, com todos os direitos reservados.