dc.descriptionTese de mestrado, Medicina Dentária, Universidade de Lisboa, Faculdade de Medicina Dentária, 2014pt_PT
dc.description.abstractObjetivo: O presente estudo laboratorial foi realizado com o objetivo de avaliar a influência da distância da fonte de radiação luminosa e do tipo de fotopolimerizador na microdureza de diversas resinas compostas e ainda avaliar a capacidade de polimerização de diversas resinas aplicando radiação luminosa emitida por diferentes fotopolimerizadores a diferentes distâncias. Materiais e métodos: Foram fabricados 180 discos de compósito com 2 mm de espessura e 5 mm de diâmetro. Foi avaliada a eficácia de três fotopolimerizadores LED, com diferentes intensidades (800 mW/cm2; 1.100-1.300 mW/cm2; 2.000 mW/cm2) a diferentes distâncias (0 mm, 2 mm, 4mm e 6mm) na capacidade de fotopolimerização de três compósitos nanohíbridos: Herculite Ultra (Kerr), Filtek Supreme XTE (3M ESPE) e GandioSO (VOCO). Foram efetuados testes de microdureza Knoop no topo e na base de cada espécime. Seguidamente calculou-se o ratio de microdureza, considerando-se que valores iguais ou superiores a 0,80 correspondiam à correta polimerização na profundidade de 2 mm de compósito. Os dados de microdureza do topo foram analisados com testes não paramétricos, segundo o método de Kruskal-Wallis, seguido de testes Mann-Withney com correção de Bonferroni. Testes T-Student foram utilizados para avaliar o ratio de microdureza (alfa=0,05). Resultados: O tipo de resina e a intensidade de radiação influenciam de forma estatisticamente significativa (p<0,05) os valores de microdureza no topo dos espécimes. Avaliando a influência da distância observou-se não existirem diferenças estatisticamente significativas (p>0,05). Uma correta polimerização na profundidade foi conseguida no grupo da resina GrandioSO para todas as intensidades e distâncias. No grupo das resinas Filtek Supreme XTE e Herculite Ultra o mesmo não foi conseguido. Conclusão: A microdureza das resinas não é influenciada pela distância da fonte de radiação luminosa, sendo no entanto influenciada pelo tipo de resina e intensidade luminosa. Relativamente à capacidade de polimerização conclui-se ser influenciada pela distância do fotopolimerizador, tipo de resina e intensidade de radiação.pt_PT
dc.description.abstractObjective: The aim of this laboratory study was to evaluate the influence of distance from the source of light irradiation and the type of curing on the microhardness of various resin composites and also assess the ability of polymerization of various resins applying radiation emitted by different light curing units at different distances. Materials and methods: One hundred eight resin composite disks with 2 mm thick and 5 mm in diameter were prepared. The effectiveness of three LED curing light was evaluated with different intensities (800 mW/cm2; 1.100-1.300 mW/cm2; 2.000 mW/cm2) at different distances (0 mm, 2 mm, 4 mm e 6 mm) on the ability of photopolymerization of three monohybrid composites: Herculite Ultra (Kerr), Filtek Supreme XTE (3M ESPE) e GandioSO (VOCO). Knoop microhardness tests were performed on the top and bottom of each specimen. Then microhardness ratio was calculated, a minimum of 0,80 was considered as a correct of depth in the polymerization of 2 mm of composite. The top of the microhardness data were analysed with nonparametric tests, according to the method of Kruskal-Wallis followed by Mann-Whitney tests with Bonferroni correction. Student t-tests were used to evaluate the microhardness ratio (alpha=0,05). Results: The type of resin and the intensity of radiation influence statistically significantly (p<0,05) microhardness values on the top of the specimens. Evaluating the influence of the distance was observed no statistically significant differences (p> 0.05). A correct polymerization in depth was achieved in the GranioSO resin group for all intensities and distances. In the group of resins Filtek Supreme XTE and Herculite Ultra the same was not achieved. Conclusion: The microhardness of the resins is not influenced by the distance from the source of light radiation, but is influenced by the type of resin and light intensity. Concerning the capacity of polymerization is concluded to be influenced by the distance of curing, resin type and intensity of radiation.pt_PT
dc.language.isoporpt_PT
dc.rightsopenAccesspt_PT
dc.subjectMateriais dentários - compósitospt_PT
dc.subjectTeses de mestrado - 2014pt_PT
dc.titleInfluência da distância e intensidade da radiação luminosa na capacidade de fotopolimerização de um compósitopt_PT
dc.typemasterThesispt_PT
thesis.degree.nameMestrado Integrado em Medicina Dentáriapt_PT
dc.identifier.tid201268388pt_PT
dc.subject.fosDomínio/Área Científica::Ciências Médicas::Medicina Clínicapt_PT
Aparece nas colecções:FMD - Dissertações de Mestrado

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
ulfmd02965_tm_Leticia_Delgado.pdf494,59 kBAdobe PDFVer/Abrir


FacebookTwitterDeliciousLinkedInDiggGoogle BookmarksMySpace
Formato BibTex MendeleyEndnote 

Todos os registos no repositório estão protegidos por leis de copyright, com todos os direitos reservados.