Utilize este identificador para referenciar este registo: http://hdl.handle.net/10400.5/96039
Registo completo
Campo DCValorIdioma
dc.contributor.advisorNeves, Maria Cristina Bettencourt-
dc.contributor.advisorBettencourt, Ana Francisca de Campos Simão-
dc.contributor.authorAbrantes, Joana Catarina Martins-
dc.date.accessioned2024-12-06T10:19:49Z-
dc.date.issued2024-07-25-
dc.identifier.urihttp://hdl.handle.net/10400.5/96039-
dc.description.abstractObjetivo: Avaliar a influência de processos de envelhecimento químico e físico na microdureza, resistência à flexão e módulo de flexão de uma resina acrílica impressa em 3D com e sem incorporação de clorexidina (CHX). Materiais e Métodos: Um total de 64 espécimes com forma de paralelepípedo (64 x 10 x 3,3 mm) foram fabricados utilizando uma resina para impressão 3D (Denture 3D+, NextDent®), com 0% e 2,5% de CHX (grupo experimental). Os espécimes de cada grupo foram divididos em 4 grupos: sem envelhecimento (controlo), envelhecimento físico, envelhecimento químico e envelhecimento químico e físico (n=8). O envelhecimento físico consistiu em 1700 ciclos de flutuações térmicas (5-55ºC). O envelhecimento químico envolveu a imersão dos espécimes em saliva artificial com pH=3 (8h/dia) e pH=7 (16h/dia) durante 60 dias. A microdureza foi avaliada mediante uma ponta diamantada Knoop e as propriedades de flexão através de um teste de resistência à flexão em 3 pontos. Os resultados obtidos foram analisados através de testes não paramétricos de Kruskal-Wallis e testes de Mann-Whitney com correção de Bonferroni, e, mediante testes ANOVA de 2 dimensões, ANOVA de 1 dimensão seguida de testes post-hoc segundo Tukey e T-test. Considerou-se um nível de significância de 5%. Resultados: O envelhecimento químico afetou a microdureza das resinas 0% (p=0,005) e 2,5% CHX (p=0,014), e em combinação com o físico a microdureza (p<0,001) e módulo de flexão (p=0,014) da resina 0% CHX, comparativamente aos grupos controlo. A incorporação de 2,5% de CHX reduziu a microdureza dos controlos (p=0,010), e afetou a resistência à flexão, aumentando o módulo de flexão, para todos os tipos de envelhecimento (p<0,001). Conclusões: O envelhecimento químico tanto isoladamente como combinado com o físico, afetou as propriedades analisadas. A incorporação de CHX (2,5%) reduziu a microdureza e a resistência à flexão da resina, aumentando o seu módulo de flexão.pt_PT
dc.description.abstractObjective: To evaluate the influence of chemical and physical aging processes on the microhardness, flexural strength and flexural modulus of a 3D printed acrylic resin with and without chlorhexidine (CHX) loading. Materials and Methods: A total of 64 parallelepiped-shaped specimens (64 x 10 x 3,3 mm) were fabricated using a 3D printing resin (Denture 3D+, NextDent®) with 0% and 2,5% CHX (experimental group). The specimens in each group were divided into 4 groups: no ageing (control), physical ageing, chemical ageing and chemical and physical ageing (n=8). Physical ageing consisted of 1700 cycles of thermal fluctuations (5-55ºC). Chemical ageing involved immersing the specimens in artificial saliva at pH=3 (8h/day) and pH=7 (16h/day) for 60 days. Microhardness was assessed using a Knoop diamond tip and flexural properties using a 3-point flexural strength test. The results obtained were analyzed using non-parametric Kruskal-Wallis tests and Mann- Whitney tests with Bonferroni correction, as well as 2-dimensional ANOVA, 1-dimensional ANOVA followed by Tukey post-hoc tests and T-test. A significance level of 5% was considered. Results: Chemical ageing affected the microhardness of the 0% (p=0,005) and 2,5% CHX resins (p=0,014), and in combination with physical ageing the microhardness (p<0,001) and flexural modulus (p=0,014) of the 0% CHX resin, compared to the control groups. The incorporation of 2,5% CHX reduced the microhardness of the controls (p=0,010), and decreased the flexural strength, increasing the flexural modulus, for all types of ageing (p<0,001). Conclusions: Chemical ageing, both isolated and in combination with physical ageing, affected the properties analyzed. The incorporation of CHX (2,5%) reduced the microhardness and flexural strength of the resin, increasing its flexural modulus.pt_PT
dc.language.isoporpt_PT
dc.rightsembargoedAccesspt_PT
dc.subjectTeses de mestrado - 2024pt_PT
dc.subjectSaúde Oralpt_PT
dc.titleInfluência do envelhecimento na microdureza e resistência à flexão de resinas acrílicas de impressão 3D incorporadas com clorexidinapt_PT
dc.typemasterThesispt_PT
dc.date.embargo2027-07-25-
thesis.degree.nameMestrado Integrado em Medicina Dentáriapt_PT
dc.identifier.tid203718712pt_PT
Aparece nas colecções:FMD - Dissertações de Mestrado

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
Dissertação_MIMD_Joana_Abrantes_2023-2024.pdf2,42 MBAdobe PDFVer/Abrir    Acesso Restrito. Solicitar cópia ao autor!


FacebookTwitterDeliciousLinkedInDiggGoogle BookmarksMySpace
Formato BibTex MendeleyEndnote 

Todos os registos no repositório estão protegidos por leis de copyright, com todos os direitos reservados.