Logo do repositório
 
Publicação

Estudo comparativo de duas macrogeometrias em implantologia

datacite.subject.fosCiências Médicas::Medicina Clínicapt_PT
dc.contributor.advisorChen, André Tsou
dc.contributor.advisorFrancisco, Helena
dc.contributor.authorPoliakov, Artiom Viatcheslavovitch
dc.date.accessioned2018-11-23T17:17:50Z
dc.date.available2018-11-23T17:17:50Z
dc.date.issued2018
dc.descriptionTese de mestrado, Medicina Dentária, Universidade de Lisboa, Faculdade de Medicina Dentária, 2018pt_PT
dc.description.abstractObjetivo: Comparar a estabilidade primária de dois sistemas de implantes de diferentes macrogeometrias (cilíndricos e cónicos) em osso de baixa densidade, com recurso a dispositivo de frequência de ressonância. Tipo de estudo: Estudo in vitro. Materiais e métodos: Foram colocados 60 implantes Zimmer® Biomet Dental, de igual comprimento e diâmetro, em costelas de vaca. O Grupo A (grupo controlo) foi constituído por 30 implantes de macrogeometria cilíndrica e o Grupo B por 30 implantes de macrogeometria cónica. A medição da estabilidade primária foi feita com auxílio do Osstell® ISQ. Resultados: Foram verificadas diferenças estatisticamente significativas (p < 0.05) nos valores médios de ISQ entre os dois grupos de implantes analisados neste estudo: Grupo A (59.5 ± 4.3); Grupo B (69.6 ± 3.1). Conclusões: Os resultados deste estudo sugerem que, em osso de baixa densidade, conseguem-se obter valores de estabilidade primária implantar aceitáveis, sendo que implantes cónicos apresentam uma estabilidade primária superior aos implantes cilíndricos.pt_PT
dc.description.abstractObjectives: To compare the primary stability in two implant systems with different designs (cylindrical-shape and conical-shape) in soft bone, using the ressonance frequency analysis technique. Study design: In vitro study. Materials and Methods: A total of 60 Zimmer® Biomet Dental implants of equal length and diameter were placed in cow ribs. Group A (control group) consisted of 30 cylindrical-shaped implants and Group B consisted of 30 tapered implants. The measurement of the primary stability was done using the Osstell® ISQ. Results: There were statistically significant differences (p < 0.05) in the mean ISQ values between the two implant groups analysed in this study: Group A (59.5 ± 4.3); Group B (69.6 ± 3.1). Conclusions: The results of this study suggest that, even in soft bone, it is possible to achieve acceptable values of implant primary stability, having tapered implants a higher primary stability than the cylindrical ones.pt_PT
dc.identifier.tid201988488pt_PT
dc.identifier.urihttp://hdl.handle.net/10451/35443
dc.language.isoporpt_PT
dc.subjectImplantes dentáriospt_PT
dc.subjectTeses de mestrado - 2018pt_PT
dc.titleEstudo comparativo de duas macrogeometrias em implantologiapt_PT
dc.typemaster thesis
dspace.entity.typePublication
rcaap.rightsopenAccesspt_PT
rcaap.typemasterThesispt_PT
thesis.degree.nameMestrado Integrado em Medicina Dentáriapt_PT

Ficheiros

Principais
A mostrar 1 - 1 de 1
A carregar...
Miniatura
Nome:
ulfmd08695_tm_Artiom_Poliakov.pdf
Tamanho:
159.54 MB
Formato:
Adobe Portable Document Format
Licença
A mostrar 1 - 1 de 1
Miniatura indisponível
Nome:
license.txt
Tamanho:
1.2 KB
Formato:
Item-specific license agreed upon to submission
Descrição: