Logo do repositório
 
A carregar...
Miniatura
Publicação

Impact of the hydraulic loading rate on the hydrodynamic characteristics of an anaerobic fixed bed reactor treating cattle slaughterhouse wastewater

Utilize este identificador para referenciar este registo.
Nome:Descrição:Tamanho:Formato: 
REP-CCORDOVIL-0100-6916-eagri-38-03-0403.pdf290.72 KBAdobe PDF Ver/Abrir

Orientador(es)

Resumo(s)

The hydrodynamic behavior of an anaerobic fixed bed reactor (AFBR) was evaluated in the treatment of cattle slaughterhouse wastewater. The AFBR was operated at hydraulic retention time (HRT) of 14, 11 and 8 h. Stimulus-response assays were carried out with Eosin Y and the experimental data were adjusted to the single-parameter theoretical models of dispersion and N-continuous stirred tank reactors in series (N-CSTR). The experimental results of the residence time distribution curves showed that at lower flow rate, the reactor showed plug flow behavior with correlation coefficient (r) of 0.88 and number of dispersion of 0.2 for high dispersion (HD). However, at higher and intermediate flow rates, the AFBR behave as a complete mixture flow, (r) of 0.94 and 0.96, respectively. Residence time distribution curves in the AFBR showed a good approximation of the complete mixing model at hydraulic residence time of 11 and 8 h, with 5 and 2 N-CSTR reactors in series, respectively. The volume of dead zones corresponding to 43.0, 37.4 and 11.2% of the volume of the reactor for HRT of 14, 11 and 8 h, respectively, was noted, and hydraulic short circuiting were not confirmed

Descrição

Palavras-chave

dead space volume hydraulic efficiency hydraulic short circuiting residence time distribution wastewater treatment

Contexto Educativo

Citação

Engenharia Agrícola, Jaboticabal, v.38, n.3, p.403-410, may/jun. 2018

Projetos de investigação

Unidades organizacionais

Fascículo

Editora

Brazilian Association of Agricultural Engineering

Licença CC

Métricas Alternativas